N2 Reflow for High Temperature (TRN III-h)

Reflow specialized for high temperature up to 400˚C

N2 Reflow for high temperature

TRN Ⅲ- H SERIES

High Convection에 최적화된
노즐 구조 및 B/M Seal Cooling으로 고온에 최적화

사양 / Specifications

Name of model TRN III - H93M TRN III - H103M TRN III - H123M
Heating (zone) 9 10 12
Cooling (zone) 3
Voltage 3P 380V or 3P 220V
Heating temperature RT~400℃
Nitrogen atmosphere 500 ~ 2,000 ppm
Nitrogen consumption 200 ~ℓ/min 250 ~ℓ/min 250 ~ℓ/min
Length 5,590 mm 5,900 mm 6,660 mm
Width 1,600 mm
Height 1,540 mm
Passing height of parts Upper 25 mm
Lower 20 mm
Width of substrate 50 ~ 410 mm
Return STD 900 mm (±20 mm)
Collection of Flux Standard mounting
Cooling Air cooling or Water cooling (OP)
B/M Motion sensor OPTION
Nitrogen generating device OPTION

※ The specifications and data indicated above are changeable without prior notice for company’s policy and product improvement.

  1. TRN III series applied with upper and lower Oven Tube Cooling & B/M Seal Cooling offer nozzle and triple insulation, optimized for connection method of high temperature.
  • Optimized system for high temperature
    The optimized model series specialized for high temperature products are equipped with specially designed oven nozzle structure optimized for system High Convection at high temperature, B/M Seal Cooling and upper & lower Oven Tube Cooling.
  • Heater Output Monitoring (OP)
    Heater Output Monitoring (OP) saves Data as Log File by monitoring output volume (MV), status information which controls each heater. Consequently, prevent heater trouble in advance after determining overheating status.
  • RPMS- B/M Motion Sensing Monitoring (OP)
    Blow Motor Rotation Real Time Monitor : Checking normal operation of motor rotation in each zone and apply with an alarm function
  • Cooling function of equipment surface temperature (OP)
    Additional cooling radiator on the upper oven allows surface temperature down to prevent the case that surface temperature of equipment increasing high temperature (400℃ setting), set by temperature Profile condition of cooling function of equipment surface temperature (OP) is relatively increased and higher than standard temperature Profile condition.

Model Numbering

SPEC
N2 Reflow for high temperature

TRN III-h Series

Closer to Customer’s Needs!
The high temperature Reflow specialized in high temperature setting is created based on solid
foundation of TRN series with an effort of Customer Proximity.

Product features

  • · Exclusive design specialized for high temperature operation up to 400°C
  • · Exclusive parts for high temperature and proceeded parts applied
  • · Highest triple insulation
  • · Cooling function around B/M sealing
  • · Oven tube cooling function
  • · Two FMS basic mounting
  • · Able to set up temperature difference between zones up to 150°C in max
  • · Applicable for TRN III-a model specification

Main features

FMS, Heat Discharging System

Ventilation cost saving during process
by discharging the Heat outside
through the way of sealed duct

Large capacity FMS

Significantly improved cooling and
Flux dust performance
with twice larger capacity

Circulation Temperature Monitoring of FMS

Checking operation condition of
FMS in real time if abnormal,
alarm functions.

Output Monitoring of Heater Control

Detecting a problem in advance
by checking normal operation of heater and
displaying heater output on MMI

Monitoring a number of rotations of B/M

Real time monitoring spinning numbers of B/M
and checking normal operation status
of motor spinning in each zone
and alarm function applied

Oil level detection sensor for C/V chain

Sensing function of Conveyor Chain Oil
Level alerts protection of C/V chain in case of
shortage of oil with functions of alarm
and message during operation

Sensing the level of Flux capacity of FMS Function

A function that notifies the Flux PM cycle
with an alarm after detecting the Flux level in
the FMS’s Drain Bottle.

Water cooling FMS

Maximizing cooling rate and efficiency
of Flux dust collection by applying
water cooling 3X8 Radiator

Convenient Monitor Configuration

Improve user convenience with intuitive
easy-to-see configuration
of required information

RTPM

With temperature measurement inside of oven
in real time, provision of temperature
related information when changing
models does not require checking
profile.

RPPM

Monitoring conditions of O2 ppm
in all zone at all time, managing
O2 ppm Profile Graph Data
according to types of production

Interfaced Operation with Reflow

Reflow offers control operation, interfaced
between Reflow operation program
(MMI) and ESP. N2 generator is flexibly
maneuverable according to operation
conditions and production models (ppm).
Consequently achievable for energy saving.